Mark 18 Ultrapure Water Quality Analyzer
Delivery time
In stock and ready to ship
The most focused and accurate water quality analysis tool on the market. For accurate, continuous, in-situ monitoring of ultrapure water quality parameters
The Martek Mark 18 Ultrapure Water Quality Analyzer provides laboratory accuracy in a single channel on-line instrument for continuous monitoring of high purity water quality. Designed to provide maximum value and flexibility, the Mark 18 can be adapted to monitor any water quality parameter simply by selecting the appropriate sensor and program. Data is displayed in precise engineering units on a large back-lit display while both digital and analog output signals are available for external recording equipment and control devices.
Designed to withstand harsh environments, the Mark 18 utilizes protected circuitry and a unique power supply to minimize electrical noise and interference commonly found in industrial climates.
p/n 178-10
SPECIFICATIONS
Parameter |
Range |
Resolution |
Accuracy |
Sensor Type |
Temperature |
0 to 100℃ |
0.01 ℃ |
±0.10 ℃ |
Thermolinear array |
Conductivity |
0 to 2.0000 µS/cm 0 to 20.000 µS/cm 0 to 20.00 µS/cm 0 to 200.0 µS/cm 0 to 200.0 µS/cm 0 to 2000.0 µS/cm |
0.0001 µS/cm 0.001 µS/cm 0.001 µS/cm 0.01µS/cm 0.01 µS/cm 0.1µS/cm |
±0.001 µS/cm ±0.01 µS/cm ±0.01 µS/cm ±0.1 µS/cm ±0.1 µS/cm ±1 µS/cm |
2-element cell Type 316 SS |
pH ORP |
0 to 14 pH units ±1400 mV |
0.01 pH units ±1.0 mV |
±0.1 pH units ±10.0 mV |
Combination glass electrode with double junction reference |
HI, H2SO4 or NaOH |
0 to 10% by weight |
0.01% |
±0.2% |
2-element insertion-style cell. Type 316 SS |
Power |
120 / 240 volts AC, 50 / 60 Hz with fuse protection |
Printer Output |
Serial ASCII RS232C standard. Isolated analog outputs of 0 - 1, 0 - 5 volts, or 4 - 20mA DC full scale standard |
Alarm Output Signals |
DPDT Relay Contact Closures rated for 3 amps at 120 volts |
Case Dimensions |
6.5 inches (16.5 cm) width x 4.00 inches (10.2 cm) height x 7.75 inches (19.7 cm) depth behind front surface panel |
Case Weight |
3 pounds (1.37 kg) |
Mounting |
Hardware supplied for panel mounting |
Construction |
NEMA 12 aluminum enclosure coated to MIL SPECS |
Manufactured in |
USA |
ORDERING INFORMATION
Part Number |
Description |
178-10 |
Mark 18 Monitor (single channel) |
180-21-1 |
Conductivity Flow-thru Sensor with preamp for ranges 0 - 2 & 0 - 20 µS / cm |
180-21-2 |
Conductivity Flow-thru Sensor with preamp for ranges 0 - 20 & 0 - 200 µS / cm |
180-22 |
Conductivity Flow-thru Sensor with preamp for ranges 0 - 200 & 0 - 2000 µS / cm |
180-24 |
pH Sensor Assembly with preamp |
180-26 |
ORP Sensor Assembly with preamp |
180-28 |
NaOH (Caustic) Insertion Cell with preamp |
180-29 |
H2SO4 (Acid) Insertion Cell with preamp |
180-29H |
HCI (Acid) Insertion Cell with preamp |
180-51 |
Type 316 SS Flow Chamber for pH / DO sensor |
NOTE: All prices FOB Factory and include the following warranties against defects in materials or workmanship: Analyzer and Preamps- 5 years, Conductivity Sensors- Lifetime, Dissolved Oxygen Sensors- 5 years. Consult the factory for specific warranty information. Specifications and prices subject to change without prior notice.
BENEFITS
FEATURES
DETAILS
APPLICATIONS